Pre-completion sound testing is the on-site acoustic measurement required to demonstrate that a new residential building or conversion meets Part E of the Building Regulations before it can be occupied. Tests measure airborne sound insulation (through walls and floors) and impact sound insulation (through floors). The pass thresholds for new builds are DnT,w + Ctr ≥ 45 dB for airborne sound and L'nT,w ≤ 62 dB for impact sound; for conversions, 43 dB and 64 dB respectively. Testing must be carried out by an accredited body: NOVA Acoustics holds UKAS accreditation (No. 8568) for sound insulation testing. If a test fails, building control sign-off cannot be granted until remediation is completed and a passing re-test is achieved.
Sound Absorption Vs Sound Insulation? What’s the big difference?
- September 19, 2018
Sound absorption refers to the loss of sound energy when sound waves hit ceilings, walls and floors, and they are absorbed.
Materials that are absorbent are often used so that a particular building is soundproofed to reduce the amount of reverberation, which has an impact on the way a particular room sounds.
Reverberation time is an important factor, as a longer duration makes a room sound loud and noisy, causing speech to become muffled. Spaces that are designed for speech usually benefit from a shorter reverberation time of less than one second. Longer reverberation times are used for music halls to add the acoustic dynamics of that space.
Buildings including schools, concert venues, recording studios and sports halls are important when it comes to their design as sound absorption needs to be implemented effectively so that these spaces operate fully for their intended use. In offices and shared environments, Acoustic Room Dividers are increasingly used to improve speech clarity and reduce noise distractions without permanent construction.
What does sound absorption look like?
Floors, walls and ceilings are usually treated with a specific type of sound absorption, which is either porous absorbents, resonance absorbents or single absorbents.
Porous absorbents
This type of absorbent takes the form of either a fibrous material or open-celled foam. The use of fibrous material allows the sound to be absorbed as the sound waves push through so that the fibres are bent and generate heat. This conversion of acoustic energy to heat means that sounds are absorbed.
Open-celled foam consists of the air movement from the sound waves that force particles of air through passages to generate heat. The thickness of a particular material has a significant impact on how well it absorbs sound.
Resonance absorbents
This type of absorbent is made up of a mechanical or acoustic system, which oscillates, and an example of this type of absorbent is membrane absorbers, which consist of a solid plate and a compact airspace.
Cavities can be filled with porous materials so that the absorption is widened across the range of frequencies.
Single absorbents
Single absorbents are usually types of furniture or other household objects including tables and chairs. The materials vary, as do the characteristics of their absorbance. For low-frequency sounds that are below 500 Hz, then there may be some difficulty when it comes to absorbing compared to high frequencies that are above this range which are usually easier to absorb.
Sound absorption and sound insulation are not the same
When it comes to sound absorption and sound insulation, it’s important to remember that they are not the same thing. They each have different ways of helping the acoustics of a particular room or building.
Sound insulation is a technique that is used to restrict sound from travelling between separate spaces through walls, ceilings and floors.
Sound absorption occurs by converting some of the energy into heat, instead of transmitting it. This can be used in conjunction with sound insulation in order to maximise the opportunity to reduce and prevent acoustic problems from occurring, but it shouldn’t be viewed as a substitute for proper sound insulation in buildings.
Recent posts
The National Planning Policy Framework requires planning authorities in England to consider noise as a material planning consideration. It does not set noise limits. Instead, it establishes the policy principles that govern when noise assessments are required, how significance is determined, and what mitigation is appropriate. The two most important principles for developers are the agent of change principle (the party introducing a noise-sensitive use near a noise source bears responsibility for managing the acoustic consequences), and the requirement to avoid placing noise-sensitive development in high-noise locations unless unacceptable impacts can be adequately mitigated. In practice, NPPF noise policy is implemented through technical standards including BS4142 and BS8233, and professional guidance including ProPG.
BS8233:2014 is the British Standard used to assess whether residential development near roads, railways, or other noise sources can achieve acceptable internal and external noise levels for future occupants. It sets out criteria for bedrooms, living rooms, and gardens across daytime and night-time periods. The most commonly referenced targets are 35 dB LAeq during the day and 30 dB LAeq at night for bedrooms. A BS8233 assessment is almost always required for residential planning applications in noise-sensitive locations, and is often conditioned by the local planning authority. ProPG (2017) sits alongside BS8233 and provides professional guidance on how assessments should be scoped and presented. This guide covers both.